Please register or log in.
Item details add to favorites
Category Hardware
Created 2017-10-12
Owner nikesasasassa
Title decorate van cleef arpels ring lucky women imitati
Description The 13C urea breath test in the diagnosis ofHelicobacter pylori infection

The urea breath test (UBT) is one of the most important non invasive methods for detecting Helicobacter pylori infection. The test exploits the hydrolysis of orally administered urea by the enzyme urease, which H pylori produces in large quantities. Urea is hydrolysed to ammonia and carbon dioxide, which diffuses into the blood and is excreted by the lungs. Isotopically labelled CO2 can be detected in breath using various methods.Labelling urea with 13C is becoming increasingly popular because this non radioactive isotope is innocuous and can be safely used in children and women of childbearing age. Breath samples can also be sent by post or courier to remote analysis centres. The test is easy to perform and can be repeated as often as required in the same patient. A meal must be given to increase the contact time between the tracer and the H pylori urease inside the stomach. The test has been simplified to the point that two breath samples collected before and 30 minutes after the ingestion of urea in a liquid form suffice to provide reliable diagnostic information. The cost of producing 13C urea is high, but it may be possible to reduce the dosage further by administering it in capsule form.An isotope ratio mass spectrometer (IRMS) is generally used to measure13C enrichment in breath samples, but this machine is expensive. In order to reduce this cost, new and cheaper equipment based on non dispersive, isotope selective, infrared spectroscopy (NDIRS) and laser assisted ratio analysis (LARA) have recently been developed. These are valid alternatives to IRMS although they cannot process the same large number of breath samples simultaneously.These promising advances will certainly promote the wider use of the13C UBT, which is especially useful for epidemiological studies in children and adults, for screening patients before endoscopy, and for assessing the efficacy of eradication regimens.Many diagnostic methods have been developed over the past 15 years to detect Helicobacter pyloriinfection some invasive (rapid urease test, histology, culture, and polymerase chain reaction) because they cannot be performed without endoscopy, and others non invasive (serology, urea breath test (UBT) and, more recently, H pylori antigen determination on faeces). Of the latter, the UBT is being increasingly used both in pretreatment and post treatment phases.Since it was first described by Graham et al,1 the test has been modified extensively to simplify and optimise it, including changes to the dose of urea used, sample timing, test meal, and cut off values to distinguish infected from uninfected subjects. Despite these modifications, the accuracy of the test has remained high and this is the best confirmation of its robustness.The test exploits the large amount of urease produced byH pylori, as this enzyme hydrolyses the orally administered, labelled urea into ammonia and labelled CO2, which is absorbed through the mucus layer of the stomach and then transported to the lungs via the bloodstream for excretion. Isotope enrichment can be measured by various methods in breath samples collected at appropriate times.Urea can be labelled with two different carbon isotopes:14C and 13C. The main difference between them is that the former is radioactive, whereas the latter is stable. The advantages of using 14C urea are that it is cheap, so rapid that administering 14C urea in knock off van cleef alhambra mother of pearl necklace a gelatin capsule allows an accurate response to be obtained from a single 10 minute breath sample,23 and does not require any test meal. However, although the dose of 14C has become progressively smaller and the test can now be performed with 1 Ci,3 which is equal to the natural background radiation received in one day,34 the main problems are still the availability of a nuclear medicine department or centres licensed for storage and disposal of radioactive substrates, shipping difficulties, and the copious amounts of labelled tracer needed to perform large scale epidemiological studies. The use of this unstable tracer can be recommended when the number of UBTs per annum in a given gastroenterological centre is less than 2500 and 14C facilities are available on site.5In contrast, 13C is a non radioactive isotope that can be used safely for repeated testing, which is frequently required in clinical practice, and for detecting H pylori infection in children and women of childbearing age. Furthermore, 13C van cleef and arpels heart necklace replica urea has been the most widely used substrate in methodological studies performed to validate this kind of diagnostic test. Another relevant advantage of using the stable isotope is that breath samples can be sent by post or courier to remote analysis centres, thus promoting the distribution of the test, which can even be performed at home if the patients are adequately selected and instructed.6 The major drawbacks of13C urea are the higher cost compared with14C urea, and the need for expensive mass spectrometry, which is the most preferable device for measuring 13C enrichment in breath samples of subjects infected withH pylori.This review focuses on the most recent advances in the machines used to measure the 13C isotope and on the most important aspects regarding the main UBT variables.13C is measured as the13CO2:12CO2 isotope ratio and is expressed as delta over baseline (DOB) per mil () with respect to the international reference standard represented by the Pee Dee Belemnite limestone. The difference in isotope masses (45:44) is detected with extreme accuracy by the sector magnet contained in the mass spectrometer (IRMS). This equipment also requires a gas chromatograph because CO2 has to be carefully purified from the whole breath prior to introduction into the mass spectrometer. The precision of measurements made by conventional IRMS can be as high as 0.017 and this allows very low isotopic enrichments to be detected. As 13C is measured as the ratio of13CO2 to 12CO2, there is no need for a large volume of expired air and a 10 ml sample is enough to obtain reliable diagnostic information.5Furthermore, the examination results do not depend on the body mass, so it is not necessary to take this variable into account.8If a mass spectrometer is the most preferable machine for detecting13C excess in breath samples, its high price has limited the spread of the test and has prompted the biomedical industry to develop new instruments that are capable of measuring the stable isotope at a lower cost. Over the past few years, analytical devices besides IRMS have been developed to perform13CO2 and 12CO2analysis, such as infrared spectrometry910 and laser optogalvanic spectroscopy.11 Several comparative studies12 15 have shown the reliability of these new, cheaper machines in measuring 13C enrichment, thus allowing them to be considered as valid alternatives to IRMS.Table 1 presents the main characteristics of IRMS, non dispersive, isotope selective, infrared spectroscopy (NDIRS), and laser assisted ratio analyser (LARA) equipment. The advantage of IRMS is that it processes the highest number of breath samples and works in an automated manner. However, it is the most expensive and requires the longest analysis time. NDIRS does not require helium as the carrier gas and has the lowest weight and price, but it can analyse only a small number of samples and so does not need multitasking software. The LARA system has the quickest analysis time; the other characteristics are average compared with the other two machines, especially with regard to the number of samples it can process and the cost. Integrated bar code readers and the use of multitasking programs have made running IRMS instruments much easier; however, they do require more maintenance than NDIRS and LARA systems. IRMS and LARA are more suitable for gastroenterological centres requiring large quantity, automated analysis, whereas NDIRS is more suitable for small laboratories in which the daily number of assays is not high. In this light, a small, new, cheap, infrared device for examination of only two breath samples has been developed to be used exclusively in the doctor's office.16 In the endless attempt to render the test cheaper and to increase the number of laboratories where it can be performed, other investigators have shown that a gas chromatograph coupled with a mass selective detector, which is available in many analytical and biomedical settings, can also be reliably used for13C UBT.17View this table:View inlineView popupTable 1Comparison of the main characteristics of three different types of equipment for measuring the13CO2 to 12CO2 ratio in breath samplesThe 13C UBT is a simple and innocuous assay which requires only few precautions in order to obtain accurate results. Besides having to avoid several dietary constituents with a natural abundance of 13C,19 such as maize, cane, and cornflour, there is still some debate concerning both the type of antisecretory drugs that may influence the test and the optimal timing of breath testing after their discontinuation in order to exclude false negative results. This is a relevant point because many patients requesting UBT are dyspeptic and thus reluctant to discontinue their antisecretory drugs. Although there is general consensus20 25 regarding the adverse effect of proton pump inhibitors (PPIs) on the UBT (false negative results range from 17 to 61%), the timing of their cessation prior to testing is not so clear. In many clinical trials aimed at assessing the efficacy of eradication regimens, for instance, it is generally reported that patients must not have taken PPIs for at least one month before the UBT, but it has been shown that five to seven days is sufficient to reverse their adverse effect.21 23 Laineet al,24 however, suggest that patients should remain off PPIs for 14 days in order to be sure of avoiding false negative results. Although H2 blockers are regarded as antisecretory drugs with knock off van cleef alhambra diamond necklace no effect on UBT,26some recent investigations have shown that even standard and high dose ranitidine can cause up to 20% of false negative breath tests.2225 These studies have shown that the reversal of this negative effect occurs within five to seven days of drug cessation and therefore withdrawal for one week suffices to rule out any adverse influence the drugs may have on the UBT.Antibiotics, particularly those with anti helicobacter action, and bismuth preparations should be withdrawn at least one month prior to UBT, as is usually suggested.The urea dose has been progressively reduced from the 350 mg (5 mg/kg) dose initially used in the study by Grahamet al,1 thus decreasing the cost of the substrate needed to perform the test. At present three different dosages are utilised. A dose of 125 mg has been validated in the United States by Klein et al,27 who showed that a sensitivity and specificity as high as 100% can be reached with this dosage. Loganet al used 100 mg in their proposal of a standard diagnostic protocol28 and this dosage has received the greatest amount of attention in Europe. Finally, 75 mg (approximately 1 mg/kg) has been shown to be as reliable as the higher doses29 and is used satisfactorily in an increasing number of research studies.13.
Type
Price $ 50,000.00
Promotion level None